3-5-2. Hardware interface
3-5-2-1. Inline interface
The maximum inline cable length and the maximum connection unit will be varied by
the inline communication speed as shown below figure.
Using 10BASE-T
Cable length: 100m (hub to terminal, hub to hub)
Maximum 4 hubs in a system.
Maximum cable length between terminal and terminal via hubs is 500m.
Using 100Base-TX
Cable length: 100m (hub to terminal, hub to hub)
Maximum 2 hubs in a system.
Maximum cable length between terminal and terminal via hubs is 300m.
Max.100m
Max.500m
Max.100m
Max.100m Max.100m
Max.100m Max.100m
Max.100m
Max.300m
Max.100m
Configuration with Hub
10BASE-T
100BASE-TX
Terminal to terminal
10BASE-T
100BASE-TX