9.6.1 Communication Parameter Setup Command (/L={,,,}
Sets up command parameters according to the command specified next to "=". If the communication
environment command needs to be specified, this command must precede it.
Command Specification Method
FLINK /L={maximum IrDA speed, wait time until the connection is established, data
transmission/reception wait time}
Always place the parameters between a pair or braces ("{ }"). Parameters do not need to be
specified, however, commas (,,,) must be specified. If a parameter is not specified, the corresponding
default values will be used.
IrDA communication speed
Input parameter Baud rate (bps) Remark
2400 2400
9600 9600
19 K 19200
38 K 38400
57 K 57600
115 K 115.2 K
576 K 576 K
1 M 1 M
4 M 4 M Default value
Wait time until the connection is established
Specify between 0 and 3600 seconds.
If "0" is specified, the application will wait until the connection is established.
The default value is 1800 seconds.
Data transmission/reception wait time
Specify between 0 and 600 seconds.
If "0" is specified, the application will wait until the communication function is normally or
abnormally terminated.
The default value is 300 seconds.