Casio E-CON Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
(4) Measurement Time Recording Method (Rec Time)
1(None) ....... No time recorded.
2(Abs) ......... Absolute time in seconds from start of sampling
3(Rel) .......... Relative time (interval between samples) in seconds
4(Int A) ........ Absolute time calculated from sampling interval and number of
samples
5(Int R) ........ Relative time calculated from sampling interval and number of
samples
(5) Sample Data Storage Location (Store Data)
1(LIST) ........ Displays a dialog box for specifying the list (1 to 20) for storing
sample data.
3. After all the settings are the way you want, press w to return to the Advanced Setup
menu.
Trigger
Use the Trigger Setup screen to specify the following measurement start (trigger) conditions:
trigger source, trigger threshold, trigger edge.
• To change Trigger Setup settings
1. While the Advanced Setup menu is on the display, press d(Trigger).
This displays the Trigger Setup screen.
2-8
EA-100 Setup
Current setting of selected item
Selected item
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 24 25

Commentaires sur ces manuels

Pas de commentaire