Casio IT-2000D Manuel d'utilisateur Page 197

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 224
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 196
197
8.5.1 Communication Parameter Setup Command (/L={,,,}
Sets up command parameters according to the command specified next to "=". If the communication
environment command needs to be specified, this command must precede it.
Command Specification Method
FLINK /L={
maximum IrDA speed, wait time until the connection is established, data
transmission/reception wait time}
Always place the parameters between a pair or braces ("{ }"). Parameters do not need to be
specified, however, commas (,,,) must be specified. If a parameter is not specified, the corresponding
default values will be used.
IrDA communication speed
Input parameter Baud rate (bps) Remark
2400 2400
9600 9600
19 K 19200
38 K 38400
57 K 57600
115 K 115.2 K
576 K 576 K
1 M 1 M
4 M 4 M Default value
Wait time until the connection is established
Specify between 0 and 3600 seconds.
If "0" is specified, the application will wait until the connection is established.
The default value is 1800 seconds.
Data transmission/reception wait time
Specify between 0 and 600 seconds.
If "0" is specified, the application will wait until the communication function is normally or
abnormally terminated.
The default value is 300 seconds.
Vue de la page 196
1 2 ... 192 193 194 195 196 197 198 199 200 201 202 ... 223 224

Commentaires sur ces manuels

Pas de commentaire