Parameter Number Parameter Name Value Notes
Parameter7[1] WahWaveform 00 - 7F Note1
Parameter7[2] Wah Rate 00 - 7F
Parameter7[3] Wah Depth 00 - 7F
Parameter7[4] TrmWaveform 00 - 7F Note2
Parameter7[5] Trm Rate 00 - 7F
Parameter7[6] Trm Depth 00 - 7F
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.28 Wah Auto Pan
Parameter Number Parameter Name Value Notes
Parameter7[1] WahWaveform 00 - 7F Note1
Parameter7[2] Wah Rate 00 - 7F
Parameter7[3] Wah Depth 00 - 7F
Parameter7[4] PanWaveform 00 - 7F Note2
Parameter7[5] Pan Rate 00 - 7F
Parameter7[6] Pan Depth 00 - 7F
Parameter7[7] Pan Manual 00 - 7F Note3
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note3 : For information about the relationship between setting values and send/receive values, see the “39.2 –64 - 0 - +63
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.29 Compressor Wah
Parameter Number Parameter Name Value Notes
Parameter7[1] Cmp Thresh 00 - 7F
Parameter7[2] Cmp Level 00 - 7F
Parameter7[3] WahWaveform 00 - 7F Note1
Parameter7[4] Wah Rate 00 - 7F
Parameter7[5] Wah Depth 00 - 7F
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.30 Compressor Distortion
Parameter Number Parameter Name Value Notes
Parameter7[1] Cmp Thresh 00 - 7F
Parameter7[2] Cmp Level 00 - 7F
Parameter7[3] Dst Gain 00 - 7F
Parameter7[4] Dst Level 00 - 7F