5. Cable Specifications
5.1 For Chain Connection And Short Length
Length; 1 meter or less
1 2 3 4 5 6
M axmim um
1m
Modular plug
(c omppa tible wit h 6/ 6-
6F R S YK (S abyo
Industrial)
1 2 3 4 5 6
Cable(see Table 5.1)
Table 5.1 Specifications of the cable
Cable
Conductor 20/0.1A
Insulator Semi-hard material P.V.C.
Core wire
Finish of external shape 20/0.1A
Insulator P.V.C. Sheath
Finish of external shape
φ4.3±0.1mm
Conductance resistance
0.12Ω/m or less
Characteristics
Insulation resistance
50MΩ or more
Pin layout diagram of cable for chain connection and short distance (pin-to-pin straight connection)
Wiring
Pin no. Signal Pin no. Signal
1 IRS+ 1 ORS+
2 IRS- 2 ORS-
3 ISD+ 3 OSD+
4 ISD- 4 OSD-
5 ORD+ 5 IRD+
6 ORD- 6 IRD-
Cradle at lower
position under the
chain connection
Cradle at higher
position under the
chain connection
View from side
View from top
Fig. 5.1
Fig. 5.2
Vue de la page 37