Casio GRAPH25+ E, GRAPH35+ E, GRAPH75+ E Manuel d'utilisateur Page 432

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 484
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 431
• From the menu that appears after you select “Photogate” as the sensor, select
[Gate] or [Pulley].
[Gate] ................Select this option when using the Photogate sensor alone.
[Pulley] ..............Select this option when using the Photogate sensor along with a
smart pulley.
5(None) ......... Select this option to disable the SONIC channel.
• Mic Channel (EA-200 only)
For this channel, the sensor is automatically set to Built-in (External) Microphone.
However, you need to configure the settings described below.
1(Snd) ........... Select this option to record elapsed time and volume 2-dimensional
sampled sound data (elapsed time on the horizontal axis, volume on
the vertical axis).
2(FFT) ........... Select this option to record frequency and volume 2-dimensional
sampled sound data (frequency on the horizontal axis, volume on the
vertical axis).
5(None) ......... Select this option to disable the Mic channel.
4. Repeat steps 2 and 3 as many times as necessary to configure all the channels you want.
5. After all the settings are the way you want, press w.
• This returns to the Advanced Setup menu.
Note
• When you select a channel on the Channel Setup screen, the sampling range of the
selected channel appears in the bottom line of the screen.
In the above example, the range of the temperature sensor assigned to CH2 appears on the
display.
If the sampling range value is too long to fit on the display, only the part of the value that fits
on the display will be shown.
• Whenever the current Sample Setup (page 3-5) and Trigger Setup (page 3-8) settings
become incompatible due to a change in Channel Setup settings, these settings revert
automatically to their initial defaults. Selecting the Mic channel with Channel Setup while
the Sample Setup has “Extended” selected for the sampling mode, for example, will cause
the sampling mode to change automatically to “Fast” (which is the initial default setting
when the Mic channel is selected). For information about the channels that can be selected
for each sampling mode, see “Sample Setup” (page 3-5).
3-4
Using Advanced Setup
Vue de la page 431
1 2 ... 427 428 429 430 431 432 433 434 435 436 437 ... 483 484

Commentaires sur ces manuels

Pas de commentaire

Trust 18347 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Torby na notebooki Trust 18347.
Dostarczamy 1 pdf podręczników Trust 18347 do pobrania za darmo według typów dokumentów: Arkusz Danych


Trust 18347 Arkusz Danych (1 strony)


Marka: Trust | Kategoria: Notebook cases | Rozmiar: 0.39 MB |

 




Więcej produktów i instrukcji dla Torby na notebooki Trust

Modele Rodzaj dokumentu
18417 Arkusz Danych   Trust 14” Ultrabook Sleeve, 1 strony
18287 Arkusz Danych   Trust 18287, 1 strony
18402 Arkusz Danych   Trust 18402, 1 strony
18238 Arkusz Danych   Trust Valletta, 1 strony
17739 Arkusz Danych   Trust Avola, 1 strony
18288 Arkusz Danych   Trust 18288, 1 strony
18227 Arkusz Danych   Trust Isotto, 1 strony
18472 Arkusz Danych   Trust 16" Notebook Bag XL, 1 strony
18286 Arkusz Danych   Trust 18286, 1 strony
19761 Arkusz Danych   Trust Sydney, 1 strony
18886 Arkusz Danych   Trust 18886, 1 strony
18366 Arkusz Danych   Trust 13.3-14" Ladies Ultrabook Bag, 1 strony
17559 Arkusz Danych   Trust Sydney 18.4", 1 strony
17674 Arkusz Danych   Trust Evora 10.1" Netbook Carry Bag & Lapdesk, 1 strony
18285 Arkusz Danych   Trust 18285, 1 strony
17740 Arkusz Danych   Trust Milazzo 16", 1 strony
17037/OT1 Arkusz Danych   Trust 17037/OT1, 1 strony
17020/OT1 Arkusz Danych   Trust 17020/OT1, 1 strony
16580/KIT Arkusz Danych   Trust 16580/KIT, 1 strony
16962 Arkusz Danych   Trust Vertico 10" Netbook Carry Bag, 1 strony