74
Appendix B: Command Tables
Command 3 - SAMPLE AND TRIGGER SETUP
∗1 A sample time to 0.5 should be used whenever an external clock is specified as the clock source.
Sample Time Number of Samples Record Time
0.001 to 16000 Number of seconds 1 Real-time data sampling. * 0 Off
(* 0.5) 1 Absolute time recording
1 to 512 Number of samples 2 Relative time recording
(* 20)
Trigger Source Trigger Threshold Trigger Edge Clock Source
0 Off 0 Falling edge * 0 Timer (sampling time)
* 1 Manual ([TRIGGER] key) * 1 Rising edge 1 [TRIGGER] key
2 CH1 (±10V) ±10 (V) 2 CH1 (±10V)
3 CH2 (±10V) ±10 (A) 3 CH2 (±10V)
4 CH3 (±10V) (default = 1) 4 CH3 (±10V)
5 CH1 (0-5V)
1 to 100 (k) 5 DIG IN clock
6 CH2 (0-5V) 0 to 5 (V)
7 CH3 (0-5V) (default = 1)
8 DIG IN clock
9 DIG IN 4-bit data 0000 - 9999 (D3-D0)
0 : LOW
1 : HIGH
2 - 9 : Don't care
(default = 0001)
Clock Threshold Clock Edge Prestore Data % Filter
±10V 0 Falling edge 0 to 100 * 0 No filtering
±10A * 1 Rising edge (default = 0) 1 5-point S-G smoothing
(default = 1) 2 9-point S-G smoothing
3 17-point S-G smoothing
When a clock source (2, 3, or 4) 4 25-point S-G smoothing
is specified for an analog channel. 5 3-point median filtering
6 5-point median filtering