23.2 Data Management Parameter
These are information acquisition and operation command parameters for this Instrument's Data Manager PC application.
Parameter ID R/W Block Size Array Min-Def-Max Description
Ps Category 0005 W 000000 7 01 00-00-7F Specifies the category ID of
the parameter set that
corresponds to an operation.
Ps Memory 0006 W
7 01 00-00-7F Specifies the memory ID of
the parameter set that
corresponds to an operation.
Ps Number 0007 W
14 01 0000-0001-3FFF Specifies the number of the
parameter set that
corresponds to an operation.
Ps Data Type 0008 R
8 01 00-00-FF This the data type of the
parameter set in the
specified category.
Compatibility is provided
between models with the same
type.
Current Ps Existence 0009 R
1 01 00-00-01 Whether a parameter set
exists in the specified
category (0: No, 1: Yes).
Current Ps Protect 000A R
1 01 00-00-01 Protect status of a
parameter set data in the
specified category (0: Off,
1: On).
Current Ps Size 000B R
32 01 00000000-00000000-FFFFFFFF Size of a parameter set in
the specified category/
number (bytes).
Current Sub Ps Size 000C R
32 01 00000000-00000000-FFFFFFFF Total size of a parameter
sets under the specified
category (bytes).
Current Ps Name 000D R
8 08 00-20-7F Name of a parameter set in
the specified category
(ASCII characters).
Max Ps Size 000E R
32 01 00000000-00000000-FFFFFFFF Maximum size of parameter
sets in the specified
category (bytes).
Max Ps Number 000F R
14 01 0000-0000-FFFF Maximum number parameter
sets in the specified
category (bytes).
Current Free Size 0010 R
32 01 00000000-00000000-FFFFFFFF Size of current parameter
set free space in the
specified category (bytes).
Max Free Size 0011 R
32 01 00000000-00000000-FFFFFFFF Maximum size of parameter
free space in the specified
category (bytes).
Delete Ps 0012 W
1 01 00-00-01 Deletes parameter sets in
the specified category.
Values are ignored.